Allen-Bradley 1756-RM Redundancy Module ControlLogix
Allen-Bradley 1756-RM Redundancy Module ControlLogix
Allen-Bradley 1756-RM Redundancy Module ControlLogix
Allen-Bradley

Allen-Bradley 1756-RM Redundancy Module ControlLogix

SKU: 1756-RM
Categories : All Products
In Stock
  • Dimensions: 21 x 15 x 1.5 cm
  • Country of origin: USA
  • Payment: T/T, Western Union
  • Shipping port: Xiamen
1 years warranty
Delivery time: 3-7 business days
Free 30 days return

Help

If you have any questions, you are always welcome to contact us. We'll get back to you as soon as possible, withing 24 hours on weekdays.

Customer service

All questions about your order, return and delivery must be sent to our customer service team by e-mail at yourstore@yourdomain.com

Sale & Press

If you are interested in selling our products, need more information about our brand or wish to make a collaboration, please contact us at press@yourdomain.com

Configured for 1:1 primary/standby controller synchronization in ControlLogix chassis pairs, the Allen-Bradley 1756-RM (1756-RM Redundancy Module) mirrors program, I/O and tag data over a single fiber optic link.

Catalog Number And Pairing Matrix

The base catalog number 1756-RM designates the original ControlLogix redundancy module. Series letters A/B follow the dash and denote firmware/hardware track; both may coexist in a redundant pair but same-series pairing is preferred. One 1756-RM is required per chassis. A complete redundant system therefore contains two chassis, two identical controllers, and two 1756-RM modules.

Electrical & Mechanical Data

Parameter Specification
Model 1756-RM
Brand Allen-Bradley
Origin USA
Weight 0.29 kg (per Rockwell TD001); supplied sample labeled 0.04 kg shipping weight
Shipping Dimensions 21 x 15 x 1.5 cm
Operating Temp 0 to 60 deg C
Backplane Current, 5.1 VDC 1.2 A
Backplane Current, 24 VDC 120 mA
Backplane Current, 1.2 VDC 4 mA
Power Dissipation 9.0 W max
Fiber Connector LC-type, per supplied sample data
Fiber Cable 8.5/125 um single-mode, per supplied sample data
Channels 1 transmit/receive fiber, per supplied sample data
Max Link Length 10 km, per supplied sample data
Transmission Rate 1000 Mbps, per supplied sample data
Wavelength 1310 nm, per supplied sample data
Supported Controllers Two 1756-L61/-L62/-L63, or one 1756-L64, plus up to seven comm modules
Chassis 1756-A4, -A7, -A10, -A13, -A17

Note: the 1000 Mbps / 1310 nm / 10 km / LC single-mode set above is retained from the supplied sample sheet; Rockwell 1756-TD001 primarily documents 1756-RM at lower legacy sync rates, while 1756-RM2 carries the confirmed 1000 Mbps / 10 km / dual-LC profile .

ControlLogix Backplane Synchronization And Firmware Rules

The 1756-RM attaches to the 1756 backplane in any single slot and exchanges redundancy status, program image and I/O ownership data with the partner 1756-RM across the fiber link. Both primary and standby chassis must carry identical slot population, identical module types and identical major firmware revisions for redundancy-ready qualification. Studio 5000 Logix Designer plus the Redundancy Module Configuration Tool sets the primary/standby role, switch behavior and diagnostic reporting. A 1756-RM cannot be mixed with a 1756-RM2 in the same redundant pair; the sync protocol and port count are not cross-compatible .

Ordering Information

  • 1 x 1756-RM redundancy module
  • 1 x 1756-RMCx single-mode fiber cable of selected length (1756-RMC1 / RMC3 / RMC10)
  • 1 x module installation instruction sheet (Rockwell publication 1756-INxxx)
  • 1 x product label / catalog tag sleeve

Rack Pair Commissioning Notes

  • Mount one 1756-RM in each of the two redundant chassis; never install only one unit and expect automatic fallback.
  • Route the LC fiber as point-to-point between the two 1756-RM modules; do not pass the link through an Ethernet switch, media converter or patch panel.
  • Keep the fiber bend radius above the cable manufacturer minimum; tight loops on 8.5/125 um single-mode cable raise attenuation and force SYNC loss before the 10 km budget is reached.
  • Verify both chassis share the same 1756 power supply class (standard or redundant) and same backplane loading before enabling redundancy.

Technical Q&A

  • Can a single 1756-RM run a standalone non-redundant rack?

No. The 1756-RM has no standalone operating mode. It only synchronizes a primary chassis with a partner chassis that also contains a 1756-RM and a matching controller. Without the partner, the module reports a non-redundant fault and does not assume normal Hot Standby control.

  • Is online module replacement supported on a live redundant pair?

Yes, subject to rules. Remove or insert one 1756-RM while the partner chassis and its own 1756-RM remain powered and synchronized. After re-insertion, the new module must match the series and firmware major revision before it is accepted into the redundant pair.

  • Why does redundancy never reach SYNCH after replacement?

Most common cause is unequal configuration between chassis: different controller firmware, different I/O slot map, or different communication module count. The 1756-RM runs a consistency check at power-up and blocks redundancy-ready until both sides are electrically and logically mirrored.

  • Are 1756-RM and 1756-RM2 interchangeable in one system?

No. 1756-RM and 1756-RM2 use different sync protocols, port counts and data rates. Mixing them across the primary and standby chassis prevents fiber link negotiation and leaves both controllers in non-redundant or faulted state.

  • What happens to outputs during a primary failure switchover?

For supported ControlLogix redundancy, the standby controller already holds the current I/O image and program state. On primary loss, ownership transfers to the standby; locally owned 1756 I/O in the redundant chassis pair is held, not dropped, provided both chassis see the same modules.

  • How many communication modules can a 1756-L64 redundant system carry?

One 1756-L64 with a single 1756-RM supports up to seven communication modules such as 1756-EN2x or 1756-CN2x in the same chassis pair. Two 1756-L61/-L62/-L63 controllers under one 1756-RM also observe the seven-module limit per redundant system, not per chassis.

  • Does the 1756-RM draw significant backplane power?

It is not a light-load module. The 1756-RM consumes 1.2 A at 5.1 VDC, 120 mA at 24 VDC and 4 mA at 1.2 VDC, giving a maximum dissipation near 9.0 W. Account for this when sizing 1756-PA75 / PB75 or 1756-PA75R / PB75R supplies in dense racks.

  • Is external grounding required beyond chassis mount?

The 1756-RM relies on the 1756 chassis backplane and mounting rails for signal reference, but the cabinet earth must be bonded to the 1756 chassis ground stud with an adequately sized conductor. Poor cabinet earth raises common-mode noise on the fiber transceiver supply and can produce intermittent COM LED faults.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Shipping & Returns

Shipping

  • Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
  • Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
  • Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
  • Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.

Returns

  • 30-Day Window: Request a return within 30 days of receipt for eligible items.
  • Condition: Items must be in their original, factory-sealed condition with all tags.
  • Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
  • Fast Refunds: Approved refunds are processed to your original payment method within 10 days.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Warranty

Warranty

  • 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
  • Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
  • Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
  • Peace of Mind: Long-term reliability support for all your mission-critical automation parts.

Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


Secure Payment

Secure Payment

  • Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
  • Local Friendly: RMB transfers are accepted if you have a local agent in China.
  • Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
  • Data Safety: All transactions are processed through encrypted and secure banking channels.


You may also like

From our blog

Latest News and Insights

Predictive Maintenance Adoption Accelerates Across Oil and Gas Operations
Sep 13, 2026
MaxWell
Predictive Maintenance Adoption Accelerates Across Oil and Gas Operations
The oil and gas industry is accelerating adoption of predictive maintenance strategies, with over 60%...
Read More
Industrial Automation Sector Q2 2026 Financial Results Show Mixed Performance
Sep 13, 2026
MaxWell
Industrial Automation Sector Q2 2026 Financial Results Show Mixed Performance
Industrial automation companies reported mixed financial results for the second quarter of 2026, reflecting varying...
Read More
POWERCHINA Advances 1.8 GW Wind Power Portfolio to Support Egypt's Energy Transition
Sep 13, 2026
MaxWell
POWERCHINA Advances 1.8 GW Wind Power Portfolio to Support Egypt's Energy Transition
Power Construction Corporation of China is advancing a portfolio of wind power projects totaling more...
Read More
Siemens Industrial AI Strategy: From CES 2026 to Production Floor
Sep 12, 2026
MaxWell
Siemens Industrial AI Strategy: From CES 2026 to Production Floor
Siemens' industrial artificial intelligence strategy has evolved from concept demonstration to production deployment, marking a...
Read More
ABB Rotork Acquisition Analysis: Strategic Expansion in Flow Control
Sep 12, 2026
MaxWell
ABB Rotork Acquisition Analysis: Strategic Expansion in Flow Control
ABB's landmark $5.5 billion acquisition of Rotork represents a decisive move to strengthen its position...
Read More
Global Renewable Energy Trends 2026: IRENA Statistical Insights
Sep 11, 2026
MaxWell
Global Renewable Energy Trends 2026: IRENA Statistical Insights
The International Renewable Energy Agency's 2026 statistical report reveals accelerating momentum in global renewable energy...
Read More
ABB IP66/Type 4X Drives: Rugged Motor Control Solutions for Harsh Industrial Environments
Sep 11, 2026
MaxWell
ABB IP66/Type 4X Drives: Rugged Motor Control Solutions for Harsh Industrial Environments
ABB has expanded its motor control portfolio with the introduction of ACS580, ACH580, and ACQ580...
Read More
DCS Selection Guide: Matching Control Architecture to Process Requirements
Sep 11, 2026
Shopify API
DCS Selection Guide: Matching Control Architecture to Process Requirements
Selecting the appropriate distributed control system requires careful analysis of process characteristics, operational requirements, and...
Read More
Rockwell Automation TechConnectIQ: AI-Powered Support Reshapes Industrial Service Delivery
Sep 11, 2026
MaxWell
Rockwell Automation TechConnectIQ: AI-Powered Support Reshapes Industrial Service Delivery
Rockwell Automation has introduced a comprehensive suite of technology initiatives aimed at transforming how manufacturers...
Read More
Wind Farm SCADA Optimization: Maximizing Energy Yield Through Data Analytics
Sep 10, 2026
MaxWell
Wind Farm SCADA Optimization: Maximizing Energy Yield Through Data Analytics
Wind farm SCADA systems have evolved from simple monitoring tools into sophisticated data analytics platforms...
Read More